Explosion Proof LED Lighting

Explosion Proof Led Lighting Malaysia

IEP, a Malaysia-based industrial electrical power products, provides a variety of explosion proof electrical equipments ranging from Exd, Exde, Exe, Exn, Ex ia Ex p, Ex q, Ex m, etc.

FeaturesDownload

IEP FEAM EVAC-LED Lighting fixtures for LED lamps

Installation: hazardous areas – Zone 1 / 2 (Gases) – Zone 21 / 22 (Dusts)
Classification: Group II – Category 2G 2D

REFERENCE STANDARDS: Directive 94/9/EC (until April 19th, 2016) – Directive 2014/34/EU (from April 20th, 2016)
EXECUTION:
II 2 G Ex d IIC T5 / T4 /T3 Gb;
II 2 D Ex tb IIIC T85/105/160°C Db
RULES OF COMPLIANCE: EN/IEC 60079-0; EN/IEC 60079-1; EN/IEC 60079-31;
EC Type-Examination Certificate: INERIS 01 ATEX 0054X
PROTECTION DEGREE: IP66
AMBIENT TEMPERATURE: -60°C ÷ +60°C
OTHER AVAILABLE CERTIFICATES:
IECEx: IECEx INE 13.0075X;
INMETRO: CEPEL 14.2311X;
EAC: TC RU C-IT.ГБ08.В.01342;
RINA: ELE18111CS_015;
RUSSIAN MARINE CERTIFICATE (RMRS): 13.03516.315

Mechanical characteristics
Body: Marine grade copper free aluminium (control gear & lamp body)
Globe: High-temperature resistant borosylicate glass
Painting: External epoxy powders grey RAL-9006 colour
Screws: External stainless steel
Gaskets: Silicon rubber
Cable entry:
2 Threaded hole dia. 1/2” NPT (EVAC201-32LED)
1 Threaded hole dia. 1” NPT (with pole mounting kit – EVAC501-48LED)
2 Threaded holes 3/4” NPT (with universal bracket – EVAC501-48LED)

Electrical characteristics
Power supply: 120 or 230 or 277 Vac 700mA, frequency 50÷60Hz
Lamp type:
4 LED by 8W – minimum brightness 3000lm approx., led type “Cold-white” – EFFICIENCY>83% Equivalent to 150W MH
6 LED by 8W – minimum brightness 5200lm approx., led type “Cold-white” – EFFICIENCY>83% Equivalent to 250W MH
Internal wiring: High-temperature resistant silicon rubber insulation cables

On Request Accessories:
• External painting colour on request
• Threaded cable entry different than standard

IEP FEAM SFD LED – SFDE LED Floodlights for LED lamps

Installation: hazardous areas – Zone 1 / 2 (Gases) – Zone 21 / 22 (Dusts)
Classification: Group II – Category 2G 2D

REFERENCE STANDARDS: Directive 94/9/EC (until April 19th, 2016) – Directive 2014/34/EU (from April 20th, 2016)
EXECUTION:
II 2 G Ex d IIB + H2 T6…T4 or
II 2 G Ex de IIB + H2 T6…T4
II 2 D Ex tb IIIC T85°C…T135°C
RULES OF COMPLIANCE: EN/IEC 60079-0; EN/IEC 60079-1; EN/IEC 60079-7; EN/IEC 60079-31
EC Type-Examination Certificate: INERIS 01 ATEX 0018
PROTECTION DEGREE: IP66
AMBIENT TEMPERATURE: -20°C ÷ +60°C
OTHER AVAILABLE CERTIFICATES: IECEx: IECEx INE 15.0003X
INMETRO: CEPEL 15.2363X
EAC: TC RU C-IT.ГБ08.В.01342 (-60°C÷+60°C)
RINA: ELE18111CS_014
RUSSIAN MARINE CERTIFICATE (RMRS): 13.03516.315

Mechanical characteristics
Body: Marine grade copper free aluminium
Diffuser: Tempered front glass
Support: Adjustable type hot dip galvanized steel
Painting: External epoxy powders grey ral-9006 colour
Screws: External stainless steel
Gaskets: Silicon rubber
Cable entry: ISO-M20 / 3/4” NPT

IEP FEAM EVFG Lighting fixtures for LED tube lamps

Installation: hazardous areas – Zone 1 / 2 (Gases) – Zone 21 / 22 (Dusts)
Classification: Group II – Category 2G 2D

REFERENCE STANDARDS: Directive 94/9/EC (until April 19th, 2016) and Directive 2014/34/EU (from April 20th, 2016)
EXECUTION:
II 2 G Ex d IIC T6 Gb;
II 2 G Ex de IIC T6 Gb;
II 2 D Ex tb IIIC T85°C Db
RULES OF COMPLIANCE: EN/IEC 60079-0; EN/IEC 60079-1; EN/IEC 60079-7; EN/IEC 60079-31;
EC Type-Examination Certificate: INERIS 12 ATEX 023X
PROTECTION DEGREE: IP66
AMBIENT TEMPERATURE: -20°C ÷ +60°C
OTHER AVAILABLE CERTIFICATES:
IECEx: IECEx INE 13.0055X;
INMETRO: CEPEL 13.2291X;
EAC: TC-RU C-IT.Г Ъ08.B.01342 (-45°C ÷ +60°C)

Mechanical characteristics
Body: Marine grade copper free aluminium
Tubes: High-temperature resistant borosylicate glass tube
Painting: External epoxy powders grey ral-9006 colour
Screws: External stainless steel
Gaskets: Silicon rubber O-Ring
Reflectors: White stove enamelled sheet steel
Cable entry: 3/4” NPT size threaded

Electrical characteristics for LED lamps
Power Supply: 100÷240V 50/60Hz (cos ρ ≥ 0,98)
Lamp holders: Bi-Pin G13 Cap
Internal Wiring: 105° C resistant silicon rubber insulation cables
Terminals: suitable up to 4sq/mm cables

On Request Accessories:
• Pole mounting kit complete with stainless steel hardware
• Ceiling mounting kit complete with stainless steel hardware
• Pendant mounting kit complete with stainless steel hardware
• Wall/Structure mounting kit complete with stainless steel hardware
• External painting colour on request
• Electronic ballast with voltage supply different than standard
• 3h autonomy battery pack
• Protection guard

IEP FEAM Explosion Proof EXL EXIT EMRGENCY Lighting fixtures for high efficiency LED lamps
Installation: hazardous areas – Zone 1 / 2 (Gases) – Zone 21 / 22 (Dusts)
Classification: Group II – Category 2G 2D

Exd IIB T6 IP66 Explosion Proof Emergency Exit Light with “EXIT” or “KELUAR” laminate sign.

REFERENCE STANDARDS: Directive 94/9/EC (until April 19th, 2016) – Directive 2014/34/EU (from April 20th, 2016)
EXECUTION:
II 2 G Ex d IIB+H2 T6 / T5 Gb;
II 2 D Ex tb IIIC T85°C / T100°C Db
RULES OF COMPLIANCE: EN/IEC 60079-0; EN/IEC 60079-1; EN/IEC 60079-31
EC Type-Examination Certificate: INERIS 15 ATEX 0024X
PROTECTION DEGREE: IP66
AMBIENT TEMPERATURE: -60°C ÷ +80°C
OTHER AVAILABLE CERTIFICATES:
IECEx: IECEx INE 15_0030X;
INMETRO: CEPEL 15.2385X;
EAC: TC RU C-IT.ГБ08.В.01342 (-60°C÷+60°C);
RUSSIAN MARINE CERTIFICATE (RMRS): 13.03516.315

Mechanical characteristics
Body: Marine Grade Copper Free Aluminium
Diffuser: High-temperature resistant borosylicate glass
Painting: External epoxy powders grey RAL-9006 colour
Screws: External stainless steel
Reflectors: White stove enamelled sheet steel
Cable entry: 3/4” NPT size threaded c/w cable gland

Electrical characteristics
Power supply (led):
Electronic ballast 100V/240V 50/60Hz (always on – maintained)
Electronic ballast 120V/240V 50/60Hz (network only – not maintained)
Electronic ballast 230V/240V 50/60Hz (only in emergency)
Lampholders: Bi-in g5 cap (fluorescent lamp only)
Internal wiring: High-temperature resistant silicon rubber insulation cables
Terminals: Suitable up to 4sq/mm cables
Emergency unit: Emergency unit for maintained and not maintained (see technical data table)

Functional characteristics
EXL08L / EXL208L (Network only): with high brightness LEDs (350mA – 4W) supply from 120V up to 240V AC/DC
EXL08LE-SA (Always On – Maintained): with high brightness LEDs (350mA – 4W) supply from 100V up to 240V AC with charge status monitor LED system (RED; battery under charging – GREEN: battery loaded)
EXL08LE (Emergency only – Not maintained): with high brightness LEDs (350mA – 4W) supply from 100V up to 240V AC with charge status monitor LED system (RED; battery under charging – GREEN: battery loaded)

On request accessories:
• External painting colour on request
• Electronic ballast with voltage supply different than standard
• Threaded cable entry different than standard
• Self-adhesive green label with EXIT sign (language on request)